stormtech detention chamber. For pretreatment of the stormwater, each chamber unit was equipped with a Barracuda hydrodynamic separator. stormtech detention chamber

 
 For pretreatment of the stormwater, each chamber unit was equipped with a Barracuda hydrodynamic separatorstormtech detention chamber  Nominal

2694 for technical and product information or visit 7 Notes: 1. Women's Torcello L/S Henley - TGH-1W $30. StormTech chambers can also be used in conjunction with Green Infrastructure, thus enhancing the performance and extending the service life of these practices. Check pricing for all our parts. StormTech MC-4500 Specifications Storage Volume Per Chamber Note: Assumes 9” (230 mm) of separation between chamber rows, 12”. Providing Resilient Water Management Solutions to Airports Nationwide . The retention system stores rainwater below the ground, which can be reused or infiltrated into the native terrain. Where to Find Us. A summary of comparative costing information for on-site underground storm water retention/detention systems is provided in Table 2. Find a Rep. The Vortechs system’s large swirl concentrator and flow controls work together to. Over drains can be utilized to pipe water to chambers – call StormTech for details Stormtech Green Infrastructure 5-11_S08_II_ 3/11/14 10:12. StormTech underground retention/detention chambers are palletized during transit to a job site. 9. 1 PRODUCT APPLICATIONS StormTech chamber systems may function as stormwater detention, retention, first-flush storage, or someStormTech chambers can also be used in conjunction with Green Infrastructure , thus enhancing the performance and extending the service life of these practices. This extra low profile chamber allows for storage of 1. The StormTech MC-7200 chamber stands 60” tall, 100” wide, and 7 feet long, making installation 40% faster. Find a Rep. com. 12 for earth and live loads using stormtech chambers. 892. Microstrain. )To learn more about the Terre Arch™ Modular Stormwater Detention System and the other innovative products we manufacture, please contact a member of our Stormwater Team. Volumetric reduction of stormwater through infiltration. Review the status of all your orders. The proposed storm drainage system will convey runoff into an existing public main located in SW Pine Street. 6” (142 mm) chamber spacing and 40% porosity. Our interactive design tool allows you to plan a project quickly and efficiently. Fieldturf Usa in Washington | Photos | Reviews | 11 building permits. N-12 ® Pipe Retention / Detention Systems. MC-3500 & MC-4500 StormTech Chamber Installation Guide. MC-7200 StormTech Chamber Installation Guide. This new design solution is more efficient and accurate compared to anything else available today. We do have Stormtech storage chamber data available for the engineering library, but it is only useful in our stormwater products that route hydrographs: PondPack, CivilStorm and SewerGEMS. Any chambers damaged by using the “dump and push” method are not covered under the StormTech standard warranty. The Kipp Charter School has completed its latest expansion for the more than 2,000 students in attendance from pre-school to high school. Documents (13) Add to Package. N-12 Flex Pipe Installation Guide. Access installation techniques for StormTech chambers and supporting video animations. ADS PipeThe StormTech SC-160LP Chamber is 12-inches tall with an installed volume of 15 cubic feet of water for underground infiltration and detention systems. Our resilient stormwater management solutions are designed to handle both. net access, you have a variety of tools and resources at your fingertips: Receive instant order acknowledgments after order has been placed. For older versions, these can both be downloaded from selectservices. StormTech’s range initial were the SC-310 and the SC-740 in 2002, since then range has been expanded to include SC. The report presents the results of laboratory tests on two types of silica-water slurry and discusses the implications for. The StormTech MC-7200 chamber stands 60” tall, 100” wide, and 7 feet long, making installation 40% faster. Download PDF . The chambers have a 75-year design service life. remove/open lid on nyloplast inline drain a. With a footprint identical to the SC-740 chamber, the DC-780's stiffening ribs reinforce the chamber structure allowing for a maximum burial depth of 12 feet. Following the 3-Parcel Partition, proposed Parcel 1 will support a multi-family residential building with four residential wings. A small labor crew made a BIG impact on the community when installing this 1. 6 cubic feet of installed storage. 6 m) Deep Cover Applications • Designed in accordance with ASTM F 2787 and produced to meet the. blogspot. The ADS Design Studio has a variety of design tools to help you plan your next stormwater management system. and detention involves the use of StormTech® underground chambers. We have installed many of these systems, and know how to get the job done right. Care should be taken in the handling of chambers and end caps. Benefit. Located<br /> upstream of an infiltration bed, between the pretreatment<br />. StormTech Chamber Systems. Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources. Web web cs storm 500nx hardware guide; Source: cafe-dc. CULTEC and StormTech Chambers. The “Go To” Material for Stormwater Detention For the majority of applications, corrugated metal pipe (CMP) is the “go to” material for stormwater detention and infiltration. Water Management Catalog. The StormTech system is designed primarily to be used under parking lots, thus. Contact StormTech for liner fabricators and installers. The StormTech SC-160LP Chamber is 12-inches tall with an installed volume of 15 cubic feet of water for underground infiltration and detention systems. chambers shall be stormtech mc-4500 or. 4” x 25” x 12” 2,170 mm x 635 mm x 305 mm ; Chamber Storage 6. Adapted from Brown and. If your site. Web the 4u. ) Please refer to the StormTech Design Manual for a complete explanation 15" Cleanout Access For Stormtech (Non-Traffic Rated With Solid Cover) Nyloplast Detail. Calculations are Based Upon a 6” (150 mm) Stone Base Under Chambers. DC-780 6" (150 mm) StormTech Inspection Port Detail. Chamber Systems for Stormwater Management / 10 -3 SC 4 -7 SC 0/ 80 -7 DC Design Manual ® StormTech Chamber Systems for Stormwater Management Table of Contents 1. Advancing the world's water infrastructure with chambers, basins and more. Official StormTech Partners since 2003, CubicM3 offers StormTech ® stormwater chambers, the most cost-effective method to save valuable land and protect water resources. 3. 2 million (Nolte Associates, 2000). 7 ft3 (0. The StormTech chamber is designed in accordance with ASTM F2787 and AASHTO standards and manufactured in accordance with ASTM F2418, qualifying it for commercial and municipal projects. Nominal. 1. STORMTECH END CAP F/ SC-740 INFILTRATION CHAMBER. 907B ARC 24 Chamber Cluster (Plan) 908B ARC 24 Chamber At-GradeStormTech. Keep your underground stormwater detention, infiltration, and cistern systems working properly with regular inspections and required maintenance. Founded in Ireland in 2003, we are proud to be Ireland's leading stormwater and environmental solutions provider. Installation. We would like to show you a description here but the site won’t allow us. StormKeeper™ Stormwater Chambers maximize the underground storage potential where available storage depth is limited, but still provide great flexibility with minimum and maximum cover heights of 2 and 8 feet, respectively. ARC Chambers Resources. We provide stormwater best management practices (BMPs) such as retention, detention, and conveyance to maintain water quality for reuse in homes and buildings. Specifying watertight pipe stops stormwater from exiting our pipe and expanding in your soils. The StormTech SC-740 chamber optimizes storage volume in a small footprint. HydroCAD Supports Stormwater Storage Products from Advanced Drainage Systems. 4x34x16. Although the vast majority. Web More Powerful Hardware (In Particular Larger Gpu Memory) Allows. The MC-3500 and MC-4500 chambers help properly manage your rainwater. 00. The StormTech system is designed primarily to be used under parking lots thus maximizing. Calculators, configurators & design tools. Web cray cs storm supercomputer density gpu rolls insidehpc cs300. 0 ft3. About 10 inches of rain over spring and summer on an average 1,360 sf roof would yield 8,160 gallons of rainwater. ASTM F2418-23 - Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers ; ASTM F2787-13e1 ( Reapproved. The StormStorage TM tool allows you to quickly and efficiently configure a storm water system in three easy steps. 4” x 25” x 12” | 2169 mm x 635 mm x 305 mm. For most recent versions, these are included already. Maki. StormTech MC-4500 Chamber Submittal Packageは、StormTechの最新の製品であるMC-4500チャンバーの性能、仕様、設計、施工に関する詳細な情報を提供するPDF文書です。MC-4500チャンバーは、優れた構造強度とコスト効率を兼ね備えた、土地の有効活用と水資源の保護に貢献するストームウォーター管理システム. com Check Details. HANMC3500 MFG #: MC3500. StormTech Lunch & Learns. × Microsoft will be phasing out Internet Explorer soon. Stavanger Waist Bag - QBX-2 $27. TN 6. Maki. StormTech Chamber manifolds are comprised of smooth interior pipes, fittings, injection molded and prefabricated manifold sections that align with the proper spacing of the chamber rows. Stormtech Detention Chamber Systems > Spel Stormwater. If currently working on a project, visit and utilize the Design Tool. They may be installed in trench or bed configurations according to site. Example Cabling Diagrams For Common. Chamber Sizing. stormtech chamber system 888-892-2694 | ® acceptable fill materials: stormtech mc-7200 chamber systems please note: 1. Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources. Calculations are Based Upon a 6” (150 mm) Stone Base Under Chambers. HydroStor chambers provide an environmentally sustainable underground water management system that optimizes groundwater recharge and saves. To control. The chambers have a 75-year. 1 cubic feet of storage per chamber. 1-800-821-6710. 18. Any chambers damaged by using the “dump and push” method are not covered under the StormTech standard warranty. Model Specific Flow Rate Bottom Area Flow Per Model StormTech SC-160LP 4. Jellyfish removes floatables, trash, oil, debris, TSS, fine silt-sized particles, and a high percentage of particulate-bound pollutants; including phosphorus, nitrogen, metals and hydrocarbons. The CULTEC, Inc. The SC-160LP chamber was developed for infiltration and detention in shallow cover applications. HydroChain™ corrosion-resistant composite tanks, chambers and vaults can form the foundation of the stormwater system. 1. The StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. Water Management Solutions. Stormtech MC 7200. 21 ft³/unit 391 gal 0. Stormtech chambers enjoyed teaming up to keep their trucks in operation by… 𝑭𝒍𝒂𝒔𝒉𝒃𝒂𝒄𝒌: The contractor delivered on a major UPS logistics project! Dirk Hudson, P. An Isolator Row is a row of StormTech chambers that is completely encased in geotextile filter fabric and acts as a sediment trap. Tree seedlings may cost $3 to $5 or more. Other potential harmful contaminants include: Sediment. Avoid dropping, prying or excessive force on chambers during removal from pallet and initial placement. 75 maximum allowable grade (top of pavement/unpaved) 975. When used together, StormTech chambers and green infrastructure offer the most cost-effective method to save valuable land and protect water resources. Ok We are currently experiencing an issue where some projects get stuck in “pending” when a user requests drawings and reports. StormCAD is our Rational Method (peak flow) product, so storage is not a factor. This category of products is designed to remove pollutants, debris and toxic materials from water before safely returning it to its natural environment. The SC-310 and SC-740 chambers and end plates. 9 cu-ft Storage per Linear Volume, Polypropylene, Domestic. StormTech chambers are designed in accordance with Section 12. In addition to stormwater expertise, Contech offers a wide range of innovative, flexible product solutions engineered to solve your site’s unique challenges and reduce long term maintenance costs. 4. StormTech MC-4500 Specifications Storage Volume Per Chamber Note: Assumes 9” (230 mm) of separation between chamber rows, 12” (300 mm) of perimeter in front of the end caps, and 24” (600 mm) of cover. 2. Introduction. Australian Tanks also manufacture larger systems consisting of 15,000 – 20,000 – 25,000 and 45,000 litre inter-connectable tanks. MC-4500™ Chamber Information Sheet - StormTech . stormtech end cap stormtech chambers stormtech chamber stormtech end cap dual wall perforated hdpe underdrain ads geosynthetics 601t non-woven geotextile ads geosynthetics 601t non-woven geotextile foundation stone beneath chambers foundation stone beneath chambers 5 mc-3500 technical specifications part # stub b c mc3500iepp06t 6" (150 mm) 33. This document does not address setting up a hydrograph or connecting inlet and outlet devices. Derived as Cost per 10m length of street (then scaled accordingly). The StormTech SC-160LP Chamber was developed for infiltration and detention in shallow cover applications. 4 (aashto. The Application. Start a Project. Underground Stormwater Chambers. Stormtech MC4500. 1. It is different from a dry pond in that it maintains a permanent pool of water between storm events. StormChambers maximize storage volume in limited footprints due to their ability to be installed in up to four layers. Because the native soils are very sandy, “very little, if any. Connect with Bishop Mays Inc:StormTech at 860. Advanced Drainage Systems - Pipe & Water Management SolutionsHigh stormwater flows can reduce the effectiveness of water quality facilities by re-suspending sediments and flushing captured floatables. The Ripple Effect. (ADS). Reduce Flood Damage with ADS Pipe Detention! Fast and safe installation Watertight joints 20 ft pipe sticks Install HP Storm polypropylene pipe for…Stormtech Chamber and Cap MC3500 - ADS Tigre . Because of this, we did not build the site to be used with IE. To place an order, email your Purchase Order to CT-Orders@cultec. backfill method. A high-performance, vortex hydrodynamic separator, the Barracuda removes total suspended solids. Chamber size ranges from 15 cubic feet of minimum installed storage to 162. Important Terms: StormTech chambers can also be used in conjunction with Green Infrastructure , thus enhancing the performance and extending the service life of these practices. stormtech chamber concrete collar pavement 12" (300 mm) min width concrete slab 6" (150 mm) min thickness 8" nyloplast inspection portThis allows StormTech chambers to be easily used within any HydroCAD model for stormwater storage, detention, or infiltration. Figure 7. Web the 4u midplane board connects the gpu sxm. The Jellyfish Filter is a stormwater quality treatment technology featuring high flow pretreatment and membrane filtration in a compact stand-alone system. StormTech is a leader in the underground stormwater chamber industry and offers a high-quality and leading edge product line. Stormtech Chamber and Cap MC3500 - ADS Tigre . Stormtech Detention Chamber Systems > Spel Stormwater. 15. StormTech chambers can also be used in conjunction with Green Infrastructure , thus enhancing the performance and extending the service life of these practices. Save valuable land and protect water resources with StormTech stormwater chambers. note: all dimensions are nominal nominal chamber specificationsStormTech - SC-740 - Stormwater Chamber by StormTech - a division of Advanced Drainage Systems, Inc. Size (L x W x H) 85. a perforated standpipe or underdrain covered in gravel is used in an earthen detention basin. Stormtech’s new stormwater chamber pushes the envelope of this technology to a new level. Stormtech SC740. . The. Web web cs storm 500nx hardware guide; Web cs storm gamemodd instruction installing mods general. The SC-160PL low-profile design, allows for reduced cover below the standard 18 to 24” and offers an option for sites that may have otherwise proven too shallow for the technology. StormTech. 15,000 cubic feet. 5 corrugation valley hdpe, etc. These technologies provide an opportunity for infiltrating runoff from roofs, walkways, parking lots, and low. 2) Note: Assumes 6” (150 mm) of row separation and 18” (450 mm) of cover. Careers. Drainage Handbook. The StormTech system is designed primarily to be used under parking lots, thus maximizing land usageOn open bottomed, high-density polyethylene infiltration chamber for subsurface retention or detention of stormwater run off. Performance of underground infiltration structures varies by manufacturer and system design. N-12® HDPE (per ASTM F2648) Pipe for Agricultural Drainage Installation Guide. contact stormtech for more information. Triumph Geo-Synthetics’ goal is providing innovative material solutions for your construction projects in Anaheim, CA. Add to cart. chambers shall meet the requirements of astm f2418, "standard specification for polypropylene (pp) corrugated wall stormwater collection. C. 6 cubic feet of installed storage. the listed aashto designations are for gradations only. $196. Providing Resilient Water Management Solutions to Airports Nationwide . 11 m)About the product. Using GreenBlue Urban’s Pavement Support System for stormwater storage is a cost-effective and versatile alternative to dry-wells, underground tanks, and other storage options. We guide and inform global communities on how to stop plastic and urban pollution at the source – the home, the business and the stormwater drain. StormTech chambers also offer a major advantage and eliminate costly accidents due to wildlife interference by storing water underground and eliminating open detention and detention ponds that attract waterfowl. Stormtech Underground Storm Chambers. End caps must be stored standing upright. 529. Stormtech Detention Chamber Systems > Spel Stormwater. Your browser does not support the video tag. 45 sf 0. Stormtech chambers bring a new level of practicality, speed and. Stormtech, a division of ATS, is a leading supplier of chambers for stormwater management. . AtlanVault. ’s post This post is unavailable. StormTech ® is a registered. Start a Project. HydroCAD can be used to route a hydrograph through a pond. 25 minimum allowable grade (unpaved with. These are ADS Stormtech MC-7200 chambers for underground detention out at the McBee's Coffee N Carwash project site in Smithville, MO. N-12 MEGA GREEN™. is the manufacturer of CULTEC Contactor® and Recharger® Plastic Stormwater Detention/Retention Chambers,. ASTM F2418-23 - Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers ; ASTM F2787-13e1 ( Reapproved. A new product to the StormTech line is the SC-160LP water detention chamber. Detention Chambers Buried Under New Athletic Stadium. Multiple cartridge heights. 459 ft³/ft 52. PE E T S. Hilliard, Ohio 43026. The StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. What's New. The program is continually updated as new research data becomes available. Stormwater Chambers. MC4500 Stormtech Chambers. Detention / Infiltration. For pretreatment of the stormwater, each chamber unit was equipped with a Barracuda hydrodynamic separator. Find a Rep. Sign in or join now to see Dirk Hudson, P. 0 Introduction<br />. The relevant equations are: Equation 1: Orifice: Q=CA√2gh. StormTech Chambers. Riser pipes or curb cuts lead surface storm water to subsurface vaults or systems of large diameter interconnected storage pipes or chambers. 3m3/m2) [minimum] of storage. Stormwater retention/detention systems vary widely in design, from openStormwater Storage Chambers. Coral springs storm 90 csstorm90. Women's Torcello L/S Henley - TGH-1W $30. 73 ft 3 (0. The retention system stores rainwater below the ground, which can be reused or infiltrated into the native terrain. StormKeeper™ Stormwater Chambers maximize the underground storage potential where available storage depth is limited, but still provide great flexibility with minimum and maximum cover heights of 2 and 8 feet, respectively. Prinsco offers four sizes of high-performance HydroStor ® stormwater chambers designed for site-specific applications such as parking lots, roadways, and commercial developments. This partnership allows ADS products to be easily used within any. It's quick and easy to connect with a representative. StormTech manufactures underground molded polypropylene chambers for stormwater retention systems. The StormTech chamber is designed in accordance with ASTM F2787 and AASHTO standards and manufactured in accordance with ASTM F2418, qualifying it for commercial and municipal projects. To get the latest StormTech chamber definitions make sure you're using HydroCAD-10. MC-7200 StormTech Chamber Installation Guide (PDF - 7 MB) Barracuda S4, S6 & S8 Concrete Installation Guide (PDF - 405 KB) SC-160LP StormTech Chamber Installation Guide (PDF - 6 MB) SC/DC StormTech Chamber Installation Guide (PDF - 6 MB) Corrugated Plastic Pipe Storm Installation Manual (Pocket Guide) (PDF - 2. TN 6. StormTech® Chambers Water Quality Water Quality Units FLEXSTORM™. Triton Stormwater Solutions Chambers are designed as an underground stormwater retention or detention chamber which also facilitates sediment management. The chambers may be used for drywells. The StormTech® underground stormwater chamber system is known as one of the most revolutionary engineered stormwater management solutions on the market. 8 cm - 1524 cm) diameter HDPE and PP pipe that offer complete compatibility - including N-12, MEGA-GREEN, SaniTite. This incorporates the site layout with various details such as the Isolator Row Plus detail, the inspection port detail, the cross section detail with acceptable aggregate types, and does this on one 24"x36" design page for your plan set. 69 1 Comment Like CommentStormtech Design - Woodard's ConcreteThe StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. The lowest unit cost represents approx. You can accomplish this by effectively. Stormwater quality through patented isolator® Row (TSS, TP and TPH removal). Our interactive design tool allows you to plan a project quickly and efficiently. 00. 021 m ) of storage for each. The StormTech Isolator Row PLUS is a row of StormTech chambers with a flared end ramp (flamp) that sits on top of one layer of ADS PLUS fabric. 6 drive configuration and status; Web more powerful hardware (in particular larger gpu memory) allows. Call StormTech at 888. The septic leaching chamber is a sturdy, lightweight polyethylene plastic unit that combines maximized infiltrative surface area and storage capacity. 7 downloads 2 Views 6MB Size. Stormwater Management Professional | Civil Engineer at Advanced Drainage Systems Report this postIsolator® Row OM Manual StormTech® Chamber System for Stormwater Management Save Valuable Land and Protect Water Resources Detention • Retention • Water Quality A division&#8230;StormTech® DC-780 Chamber Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources. Our team of engineers and support personnel can help you find what you need. StormTech Chambers. The StormTech DC-780 Chamber optimizes storage volumes in deep cover applications. Vortechs is a below-ground, engineered stormwater treatment device that combines swirl concentration and flow controls into a single treatment unit. ADS SC740 CHAMBER STORMTECH 85. StormTech® DC-780 Chamber Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources. This model can also inform facility developers and managers on the effects likely to result from proposed land-use changes that impact. Stormtech Chamber and Cap MC3500 - ADS Tigre . 44 L: Min. ADS; SC740; User guide. Care should be taken in the handling of chambers and end caps. The volume of excavation will vary as depth of cover increases. DC-780 StormTech Cross Section Detail. An Isolator Row is a row of StormTech chambers that is completely encased in geotextile filter fabric and acts as a sediment trap. Call StormTech at 888. Increasingly stringent regulations and escalating land values require developers to take extra care in managing stormwater runoff. stormtech sc-310 chambers shall be installed in accordance with the "stormtech sc-310/sc-740/dc-780 construction guide". Braen Supply Haledon. 2694 or visit our website at for technical and product information. 12 m³) of internal storage capacity or 115ft³ (3. 2. This system consisted of corrugated plastic domes fastened together to form rows of chambers which were sitting on, and backfilled with, crushed angular stone. C. The system with Stormtech chambers allows part of the retained water to infiltrate the soil and replenish the groundwater and the other part to be launched in a controlled manner in the public network. 892. HydroCAD can be used to route a hydrograph through a pond. Enter your email address to subscribe to our newsletter. Stormwater injection is a concern because storm water may contain petroleum or other organic compounds that could harm USDWs. A strip of woven geotextile is placed under the entire length of the row between the chambers and base stone. A chamber conveys water laterally through its sidewall openings, as well as through the angular stone founda-tion and backfill, to maintain a con-stant elevation in a bed. Tried and tested with 20 years. Save valuable land and protect water resources with StormTech stormwater chambers. Strong enough to sustain the impact of 18-wheelers loaded with steel. The SC-160LP chamber was developed for infiltration and detention in shallow cover applications. 00. StormTech ® is a registered. It is load-rated for extreme applications, like heavy truck or under fire access roads, offering maximum strength while allowing for utilization of valuable land. 48 m³/unit 1478. This line also allows for usage were high water tables are present or to avoid. or MC-4500 (106 ft 3) to provide stormwater detention, retention, recharge, first-flush storage or a combination designed to suit commercial. If you'd like to use a storage chamber from CULTEC or StormTech, storage chamber library files are. the stone must also be clean, crushed, angular. Eco-friendly composite HydroChain Chambers are installed surrounded by stone to maximize per. “The choice of StormChambers met the design requirements for strength in such a way that the chambers could be stacked three deep with 30 feet of cover, if needed. Introduction. Initial Anchoring of Chambers – Embedment Stone Backfill of Chambers – Embedment Stone Initial embedment shall be spotted along the centerline of the chamber evenly anchoring the lower portion of the chamber. Stormtech Chamber and Cap MC3500 - ADS Tigre . Size (L x W x H) 85. View the StormTech Video Library. The volume of excavation will vary as depth of cover increases. Detention / Infiltration. Add To Cart Add to List. Proper design of any detention system typically requires that flow routing be performed. View online (40 pages) or download PDF (26 MB) ADS StormTech DC-780, StormTech SC-310, StormTech SC-740, StormTech SC-160LP User manual • StormTech DC-780, StormTech SC-310, StormTech SC-740, StormTech SC-160LP PDF manual download and more ADS online manualsOverview. Four beds of StormTech MC-4500 detention chambers were installed to handle the stormwater storage. The StormTank Module 25 Series is a subsurface stormwater storage unit commonly used for stormwater retention, detention, infiltration, and rainwater harvesting applications. The SC-310 and SC-740 chambers and end plates. For minimum fill requirements for layers A, B and C, refer to StormTech Design Manual 2. blogspot. stormtech chambers are molded from polypropylene resin, which<br /> is inherently resistant to environmental. Stormtech Chamber and Cap MC3500 - ADS Tigre. StormTech + Green Infrastructure Benefits. The StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. The system is easy to maintain and is designed primarily to. The volume of excavation will vary as depth of cover increases.